Jira Story: Review and understand NVIDIA Network Operator installation, configuration, and upgrade in Kubernetes Source version referenced: v25.10.0 (GA) Primary sources: NVIDIA Network Operator Quick Start Guide for Kubernetes · Life Cycle Management · Platform Support · Customization & CRD Reference

This document is organized around the six review areas from the story, in order.

1. Infrastructure Prerequisites — NICs, Drivers, Kubernetes Setup

1.1 Kubernetes / tooling prerequisites

Component Requirement Notes
Kubernetes v1.30–1.34 Current GA-validated range
Helm v3.5+
Node Feature Discovery (NFD)0.15.6–0.17.0 Only one NFD instance per cluster — if GPU Operator is also installed, reuse its NFD rather than deploying a second copy
Container runtime containerd or CRI-OWhich one depends on OS — see 1.3

1.2 Hardware prerequisites

  • RDMA-capable NVIDIA network adapter — this is the non-negotiable one. Supported families:
Product Fabric Max port speedNotes
ConnectX-6 Ethernet & InfiniBand200 Gb/s IB RDMA and RoCE
ConnectX-6 Dx Ethernet 200 Gb/s RoCE
ConnectX-7 Ethernet & InfiniBand400 Gb/s IB RDMA and RoCE
ConnectX-8 SuperNIC Ethernet & InfiniBand800 Gb/s IB RDMA and RoCE
BlueField-3 DPU Ethernet 200 Gb/s NIC mode only, RoCE
BlueField-3 SuperNICEthernet 400 Gb/s NIC mode only, RoCE
  • NVIDIA GPU Operator v25.3.x+ — only required if workloads need GPUDirect RDMA (GPU-to-NIC direct memory access for GPU-to-GPU networking). Not required for network-only use cases.
  • Validated NVIDIA Data Center systems (IGX Orin, Grace ARM Server, DGX/HGX GB200 NVL72, DGX/HGX B200, RTX PRO 6000 Blackwell Server) each pair a specific CPU/GPU/NIC/OS combination — worth checking directly against the Platform Support page if targeting one of these.

1.3 Supported OS / Kubernetes platform / runtime matrix

OS Upstream K8sOpenShiftRKE2 MicroK8sRuntime
Ubuntu 24.04 LTS1.30–1.34 1.30–1.34 containerd
Ubuntu 22.04 LTS1.30–1.34 1.30–1.34 containerd
Red Hat CoreOS 4.17–4.20 CRI-O
RHEL 8 / 9 / 10 1.30–1.34 containerd + CRI-O
SLES 15 SP7 1.30–1.34 1.30–1.34containerd

1.4 The driver itself: DOCA-OFED

The operator manages a containerized DOCA-OFED driver (the successor to MLNX_OFED) rather than requiring it to be preinstalled on the host — this is one of the operator's core value props. Two delivery paths:

  • Precompiled driver container images — fastest node bring-up, no in-node compilation. GA only for generic-flavor Ubuntu 22.04/24.04 kernels; nvidia/aws/azure/oracle kernel flavors are Tech Preview with limited testing; images are currently unsigned.
  • Custom precompiled container — required for any kernel/OS combination not covered above (e.g., a non-generic cloud kernel); built from NVIDIA-provided Dockerfiles and hosted in your own registry.

2. Helm-Based Installation Steps and Configuration Options

2.1 Base install

helm repo add nvidia https://helm.ngc.nvidia.com/nvidia
helm repo update
 
helm install network-operator nvidia/network-operator \
  -n nvidia-network-operator \
  --create-namespace \
  --version v25.10.0 \
  --set sriovNetworkOperator.enabled=true \
  --wait
 
kubectl -n nvidia-network-operator get pods

 

This installs the operator controller and CRDs only — no host is touched until a NicClusterPolicy is applied (Section 3).

2.2 Custom-values install path

For anything beyond quick-start defaults, fetch the chart and drive the install from a values.yaml instead of ad hoc –set flags:

helm fetch nvidia/network-operator --version v25.10.0 --untar
# edit values.yaml
helm install network-operator ./network-operator -n nvidia-network-operator \
  --create-namespace -f values.yaml

 

2.3 Key Helm configuration areas

Area What it controls
General parameters Namespace, image pull secrets (imagePullSecrets customization for private/NGC-authenticated registries), node selectors/affinity, tolerations
NFD labels / Node Feature DiscoveryWhether the chart deploys its own NFD instance or expects one to already exist (set to avoid the GPU Operator/NFD collision noted in 1.1)
SR-IOV Network Operator sriovNetworkOperator.enabled — toggles deployment of the community SR-IOV Network Operator sub-chart, required for any SR-IOV use case
Maintenance Operator maintenanceOperator.enabled — deploys the NVIDIA Maintenance Operator sub-chart, required if you want “requestor mode” upgrades (Section 5) instead of the operator's built-in cordon/drain logic
Proxy / air-gapped settings HTTP proxy env vars for OpenShift and vanilla K8s; local-registry configuration for fully disconnected environments

2.4 Post-install verification

kubectl -n nvidia-network-operator get pods

 

All controller pods (network-operator, and any enabled sub-charts like sriov-network-operator) should reach Running. This confirms the control plane is up — it does not confirm anything about NIC configuration, which only happens once a NicClusterPolicy is applied.

3. Role and Structure of the NicClusterPolicy Resource

3.1 Role

NicClusterPolicy (mellanox.com/v1alpha1) is the single central custom resource the operator continuously reconciles against. It is effectively the declarative “desired state” for the entire host networking stack across the cluster: which driver version runs, which device plugins are active, which CNIs and IPAM are deployed, and how upgrades should behave. Everything downstream — SR-IOV networks, MacVLAN networks, IPoIB networks — depends on a healthy NicClusterPolicy first.

3.2 Structure — major spec sections

Spec field Purpose
ofedDriver DOCA-OFED driver image/repository/version, plus upgradePolicy (auto-upgrade, drain behavior, safe-load — see Section 5)
rdmaSharedDevicePlugin Configures the RDMA shared device plugin — resource naming, NIC selectors, how many pods can share a device
sriovDevicePlugin Configures the SR-IOV device plugin for VF allocation
secondaryNetwork Bundles Multus, NVIDIA IPAM (nvIpam), IPoIB CNI, and IB Kubernetes plugin settings — the plumbing behind MacVLAN/IPoIB/SR-IOV secondary networks
nicFeatureDiscovery NIC-level feature labeling (link type, capabilities) used by selectors elsewhere in the CR
docaTelemetryService Optional telemetry sidecar for NIC-level metrics
nicConfigurationOperatorHand-off point to the separate NIC Configuration Operator for firmware-level settings (not covered by Network Operator itself)

3.3 Example — minimal driver section with upgrade policy

apiVersion: mellanox.com/v1alpha1
kind: NicClusterPolicy
metadata:
  name: nic-cluster-policy
  namespace: nvidia-network-operator
spec:
  ofedDriver:
    image: doca-driver
    repository: nvcr.io/nvidia/mellanox
    version: doca3.2.0-25.10-1.2.8.0-2
    upgradePolicy:
      autoUpgrade: true
      maxParallelUpgrades: 1
      safeLoad: false
      drain:
        enable: true
        force: false
        podSelector: ""
        deleteEmptyDir: true

 

3.4 Reading status

kubectl get -n nvidia-network-operator nicclusterpolicies.mellanox.com nic-cluster-policy -o yaml

 

status:
  appliedStates:
  - name: state-multus-cni
    state: ready
  - name: state-OFED
    state: ready
  - name: state-RDMA-device-plugin
    state: ready
  - name: state-nv-ipam-cni
    state: ready
  - name: state-SRIOV-device-plugin
    state: ignore   # not configured in this CR — not a failure
  state: ready

 

state: ready at the top level means the declared policy has been fully rolled out cluster-wide. A sub-state of ignore means that feature simply wasn't requested — not an error.

3.5 Editing NicClusterPolicy after initial apply

Any manual edit affecting device plugin configuration (e.g., NIC selectors) requires a manual device-plugin pod restart — this is a standing operator limitation, independent of whether the edit was part of a version upgrade or a plain reconfiguration.

4. Supported Networking Configurations — SR-IOV, RDMA, MacVLAN, IPoIB

Mode How traffic reaches the pod RDMA model Isolation Best fit
SR-IOV A hardware Virtual Function (VF) is passed directly into the pod's network namespace via the SR-IOV CNI Direct — each VF has its own RDMA context Strong (dedicated VF per pod) Max performance, HPC/AI training, low jitter
RDMA (shared device) RDMA character devices exposed via the RDMA shared device plugin; the NIC itself stays on the host's primary interface Shared — multiple pods share one physical device's RDMA resourcesWeaker (shared) Multi-tenant workloads needing RDMA without dedicating a whole NIC/VF per pod
Host Device The entire physical NIC is PCI-passed into one pod, no sharing at all Direct, exclusive Strongest (whole device) Legacy/DPDK apps needing raw, exclusive device control
MacVLAN L2 MACVLAN sub-interface per pod, layered on a shared parent interface, typically paired with the RDMA shared device plugin for the RDMA pathShared Network-layer isolation via distinct MAC/IP per podCloud-native multi-tenant HPC needing many pods/node with distinct L2 identities
IPoIB (IP over InfiniBand)IP connectivity carried over an InfiniBand fabric via the IPoIB CNI; RDMA still available via the shared device plugin Shared Moderate Distributed storage/analytics needing ordinary IP-routable traffic on an IB fabric
SR-IOV InfiniBand SR-IOV VFs on a native InfiniBand fabric, with pkey/GUID management handled by the IB Kubernetes plugin Strong (dedicated VF + IB partition) Large-scale IB-based AI training clusters

4.1 How to choose

  • SR-IOV vs. Host Device — both give hardware-level performance, but SR-IOV slices one physical NIC into many isolated VFs (many tenants per node), while Host Device hands the entire physical NIC to a single pod (zero sharing).
  • MacVLAN vs. IPoIB — MacVLAN is the Ethernet/RoCE-oriented secondary-network pattern; IPoIB is specifically for InfiniBand fabrics where ordinary IP addressing (rather than native IB addressing) is still wanted.
  • SR-IOV InfiniBand — combines SR-IOV virtualization with native IB partitioning; typically the highest-performance option for large IB-based AI training clusters, and it's the one mode that depends on the IB Kubernetes plugin for pkey/GUID assignment.
  • All “shared” modes (RDMA shared device, MacVLAN, IPoIB) ultimately compete for the same physical RDMA resources at the node level — the device-plugin resource counts configured in NicClusterPolicy (Section 3.2) become the real admission-control mechanism for how many pods can get RDMA on a given node.

4.2 Quick Start manifests

Each mode has a ready-made NicClusterPolicy + secondary-network manifest pair in the Quick Start Guide (SR-IOV Network with RDMA, Host Device Network with RDMA, IPoIB with RDMA Shared Device, MacVLAN with RDMA Shared Device, SR-IOV InfiniBand Network with RDMA) — these are the fastest way to see a working reference for each pattern rather than building NicClusterPolicy fields from scratch.

5. Upgrade Process — Helm Upgrade Behavior and Manual NicClusterPolicy Updates

5.1 The core fact that shapes this whole process

helm upgrade only updates the operator's own controller and CRDs. It does not change the DOCA-OFED driver or any component version actually running on nodes — those live in NicClusterPolicy and must be bumped in a separate, manual step. This is the single most common source of “I upgraded but nothing changed” confusion.

5.2 Step-by-step

Step 1 — Fetch the new chart:

helm fetch https:%%//%%helm.ngc.nvidia.com/nvidia/charts/network-operator-25.10.0.tgz
tar xf network-operator-25.10.0.tgz

 

Step 2 — Apply the Helm chart update (controller + CRDs only):

helm upgrade -n nvidia-network-operator network-operator nvidia/network-operator \
  --version=25.10.0 -f values-25.10.0.yaml --force

 

Step 3 — Manually update NicClusterPolicy with the new release's component versions (driver image tag, device plugin images, etc., from that release's component matrix), then re-apply:

kubectl apply -f nicclusterpolicy.yaml

Known limitation: a devicePlugin config change without a matching image bump may not auto-restart the plugin pod — manual kubectl delete pod restart may be required.

Step 4 — Driver rollout across nodes. Governed by ofedDriver.upgradePolicy:

  • autoUpgrade — master on/off switch
  • maxParallelUpgrades — throttles concurrent node upgrades (0 = unlimited)
  • safeLoad — cordon/drain before the first containerized driver load, to prevent pods silently losing network interfaces mid-flight
  • drain — enable/force/podSelector/timeoutSeconds/deleteEmptyDir

Each node walks a tracked state machine via the nvidia.com/ofed-driver-upgrade-state label: upgrade-required → cordon-required → wait-for-jobs-required → drain-required → pod-restart-required → uncordon-required → upgrade-done (or upgrade-failed, requiring manual intervention).

Two execution modes:

  • In-place (default) — the operator's own internal scheduler performs cordon/drain/uncordon directly.
  • Requestor mode — delegates those operations to the NVIDIA Maintenance Operator via NodeMaintenance objects (MAINTENANCE_OPERATOR_ENABLED=true, maintenanceOperator.enabled: true in Helm values). Useful if node maintenance is already standardized around that operator elsewhere in the cluster.

PodDisruptionBudget caveat: drains can silently fail if PDBs aren't accounted for — drain.podSelector must be scoped precisely to the pods that actually need to move. Over-broad selectors on clusters with strict PDBs (OpenShift especially) can block the whole drain.

Manual fallback (if autoUpgrade is off): the driver DaemonSet uses OnDelete update strategy, so a bare helm upgrade leaves the old driver pod running until it's explicitly deleted or the node reboots:

kubectl drain <NODE_NAME> --pod-selector=<SECONDARY_NETWORK_POD_SELECTOR>
kubectl delete pod -n nvidia-network-operator -l app=mofed-<OS_NAME>
kubectl uncordon <NODE_NAME>

  Do this per-node in production rather than all at once, to bound blast radius.

Step 5 — Verify:

kubectl get nodes -L nvidia.com/ofed-driver-upgrade-state
kubectl get -n nvidia-network-operator nicclusterpolicies.mellanox.com nic-cluster-policy -o yaml

 

Confirm every targeted node reads upgrade-done and the CR's overall status.state is ready. If a node sticks at upgrade-failed: drain it manually (kubectl drain –ignore-daemonsets), delete its driver pod, and — if Safe Driver Loading was enabled — remove the nvidia.com/ofed-driver-upgrade.driver-wait-for-safe-load node annotation to unblock the reload.

5.3 Versioning and support cadence

Calendar versioning: YY.MM.PP. When a new major (YY.MM) ships, the prior major moves to maintenance (patch/CVE fixes only); the one before that goes EOL. At time of writing: 25.10.x = GA, 25.7.x = Maintenance, 25.4.x and earlier = EOL. Plan upgrade cadence against this rather than waiting for forced EOL migration.

5.4 Uninstall (rollback / decommission reference)

kubectl delete -n nvidia-network-operator nicclusterpolicies.mellanox.com nic-cluster-policy
helm uninstall network-operator -n nvidia-network-operator
kubectl get nicclusterpolicies.mellanox.com # expect "No resources found"

 

On OpenShift, OLM uninstall does not remove CRDs/CRs automatically — delete them explicitly afterward (oc delete crds hostdevicenetworks.mellanox.com macvlannetworks.mellanox.com nicclusterpolicies.mellanox.com).

6. Limitations and Blockers in Unsupported Environments

Limitation Effect
No RDMA-capable NIC (local dev machines, generic cloud VMs, DGX Spark)The operator's Helm chart/CRDs install fine — the controller has no hardware dependency. But NicClusterPolicy reconciles against nodes with no matching NVIDIA/Mellanox device, so NIC feature discovery, device-plugin, and driver-container states have nothing to attach to; the DOCA-OFED driver pod fails health checks or registers no usable device resources.
No VFs/RDMA devices to allocate SR-IOV, Host-Device, MacVLAN, and IPoIB network CRs show pods stuck in scheduling or CNI failure — the underlying hardware resource simply doesn't exist to satisfy the request.
Kernel/OS mismatch Precompiled DOCA-OFED driver containers are GA only for generic-flavor Ubuntu 22.04/24.04. Cloud-vendor kernels (aws/azure/oracle), custom kernels, or other distros need a custom-built precompiled driver container — meaningful extra lifecycle burden for a throwaway test environment.
NFD collisions Running NFD from both GPU Operator and Network Operator on one cluster is unsupported; a cluster already running GPU Operator must reuse its NFD instance instead of deploying a second one via the Network Operator chart.
PodDisruptionBudget conflicts Especially on OpenShift, over-broad or unset PDBs can silently block node drains during upgrade — more likely to go unnoticed on an ad hoc test cluster with no PDB discipline.
Virtualization/nesting SR-IOV VFs and true RDMA generally can't pass through multiple virtualization layers, so SR-IOV and Host-Device modes are effectively unusable inside most local VMs or cloud dev sandboxes, even when the underlying physical host has a supported NIC.

Practical conclusion: the mechanical/API layer — Helm install, CRD structure, editing NicClusterPolicy, reading status, running upgrade commands — is fully hardware-agnostic and can be exercised anywhere with a Kubernetes API server. What cannot be validated without real ConnectX/BlueField hardware is anything downstream of NIC discovery: driver loading against real silicon, VF creation, RDMA device allocation, and actual throughput/latency behavior. Local environments are useful for validating “does my NicClusterPolicy YAML apply and pass schema/reconciliation cleanly” — everything hardware-dependent should be assessed against NVIDIA's documented, validated hardware/OS matrix (Section 1) instead.

7. Summary — When and Where to Use the Network Operator

Situation Recommendation
Bare-metal/on-prem K8s cluster with ConnectX-6/7/8 or BlueField-3 NICs, GPU-to-GPU or GPU-to-storage RDMA neededUse it — primary supported scenario; pair with GPU Operator for GPUDirect RDMA
HPC/AI training cluster needing dedicated per-pod NIC bandwidth with multi-tenant isolation Use it, SR-IOV or SR-IOV InfiniBand mode
Multi-tenant cloud-native cluster where many pods need shared, moderate RDMA access Use it, RDMA shared device plugin ± MacVLAN
Distributed storage/analytics on an InfiniBand fabric needing ordinary IP addressing Use it, IPoIB mode
OpenShift environment Use it — dedicated deployment/upgrade path via OLM, including disconnected/air-gapped install support
Local dev laptop, generic cloud VM, or DGX Spark without RDMA-capable NICs Do not attempt hands-on deployment — no hardware to reconcile against; validate via documentation and CRD reference instead
Cluster already running GPU Operator's NFD Reuse that NFD instance; don't deploy a second one via the Network Operator chart
Need firmware-level NIC configuration (not just driver/CNI) Pair with the separate NIC Configuration Operator

Reference links

  • Quick Start Guide: https://docs.nvidia.com/networking/display/kubernetes25100/quick-start/quick-start-k8s.html
  • Life Cycle Management: https://docs.nvidia.com/networking/display/kubernetes25100/life-cycle-management.html
  • Platform Support: https://docs.nvidia.com/networking/display/kubernetes25100/platform-support.html
  • Customization Options & CRD Reference: https://docs.nvidia.com/networking/display/kubernetes25100/customizations/crds.html